Series HS

HS-tronic 2 with membrane keyboard

Controller for tubular motors
230 V AC with mechanical
end switches

 

 

  • Fully automatic gate controller
  • Red light forewarning
  • Command encoder for impule repition / defined OPEN-CLOSE mode
  • Slot for 2-channel-receiver
  • Switching edge input 8K2-Resistant
  • Switching edge input optical sensors
  • Input for postern / slack rope switch

HST 100 with membrane keyboard

for reversing contactor controller voltage 24 V

 

Control unit for drives with reversing contactor controller voltage 230 V and cam end switch.

  • Fully automatic gate controller
  • Red light forewarning
  • Command encoder for impule repition / defined OPEN-CLOSE mode
  • Slot for 2-channel-receiver
  • Switching edge input 8K2-Resistant
  • Switching edge input optical sensors
  • Input for postern / slack rope switch

HST 7 Sliding Gate Control Unit

Complete control unit for sliding gates with reversing contactor controller voltage 24 V AC/DC.

 

  • Connection for 6 safety edges with 8K2 terminating resistance
  • Slot for inductive evaluation
  • Slot for receiver OPEN-CLOSE or impulse repition 
  • Hold-to-run or lock 
  • Inside/outside/gatekeeper OPEN-CLOSE
  • Automatic closing with forecast lead time
  • Runtime monitoring
  • Connection for rotating beacon 230 V, 40W

HST 7 WE Sliding Gate Control Unit

Complete control unit for sliding gates with reversing contactor.

 

  • Connection for 6 safety edges with 8K2 terminating resistance
  • Slot for inductive evaluation
  • Slot for receiver OPEN-CLOSE or impule repition
  • Hold-to-run or lock
  • Inside/outside/gatekeeper OPEN-CLOSE
  • Automatic closing with forecast lead time
  • Runtime monitoring
    Connection for RED-GREEN traffic light
  • Partially opening with additional partially opening switches possible

HST 8 with Membrane Keyboard

Control unit with reversing contactor for every drive with cam end switch.

 

  • Engine output up to 3 KW
  • Operating voltage 3 x 400 V, 1 x 230 V
  • Command encoder for impulse repition / defined OPEN-CLOSE mode
  • Slot for 2 channel receiver
  • Safety edge input 8K2-resistance
  • Switching edge input optical sensors
  • EiInput for postern / slack rope switch
  • Pulse mode OPEN-STOP-CLOSE
  • Hold-to-run or lock 
  • Intermediate position Summer/Wintercircuit
  • Automatic closing, opening time and vacate time free adjustable
  • Red traffic light ON while gate movement and vacate phase
  • Green traffic light ON while gate end position OPEN
  • Plug-in module pull-in protection additional