Printable Version

Gate Control Unit ATC 100

General

The ATC 100 is easy to configure. It was developed to control 400V three-phase and 230V AC motors for push-, roll- and section-gates in industrial, commercial and private applications.

A wide field of applications is ensured through flexibility, numerous connectivity options and a variety of optional plug-on modules.

The ATC 100 has menu-assisted programming. This makes it easy to to control complex applications to achieve a variety of different tasks and functions.

 

Complete Safety for Personnel and Products

  • All parts of the system are tested before the movement of the gate
  • All safety contacts are tested before gate movement
  • An 'all clear' relay provides a second safety circuit to switch electricity off in case of other failures
  • The ATC100 is a compact unit that fulfills the latest standards for gate safety

 

The Advantages of the ATC 100

  • compact housing
  • standard AC and three-phase connection via integrated reversing contacts
  • simple, menu-guided programming via four keys
  • add-on module for protection from unauthorised access to the programming
  • malfunctions and operational states are indicated via a two-line LCD as well as via LEDs
  • integrated two-channel safety circuit for stationary safety contact strips
  • integrated plug for induction safety system ISK to monitor the moving safety contact strips at the gate
  • integrated plug for a timer
  • integrated plug for radio control unitg
  • complete of partial automatic reverse after activation of safety contract strips
  • connection plugs for easy assembly
  • ALL-IN-ONE automatic gate solution

Technical data:

Operating Voltages

  • 3 x 400 V 50/60HZ for three-phase mains supply
  • 230 V 50/60 HZ for AC mains supply
  • 65 mA /107 mA current
  • 15 VA / 24.5 VA power capacity

The maximum values apply to maximum configuration and maximum power for external 24 V components.

Fuse for external components

  • max. 10A

Fuse for internal components

  • T 2 A / 250 V glass tube 5x20 mm

Output supply 24 V DC

  • 24 V DC +/- 15%
  • 24V 250 mA
  • 6 W

For safety and error-free running of the control unit, stated maximum values must not be exceeded under any circumstances.

Motor reversing contactor

  • 2.2 KW max. maximum capacity for 230 V AC power
  • 4 KW maximum capacity for 400 V three-phase power

Relay capacities

  • 250 V / AC maximum switching voltage
  • 2.5 A / AC maximum switching current

Switching times of the safety circuits

  • =/< 25 ms STOP activated - contactor open
  • =/< 30 ms ISK activated - contactor open

Large picture

  • IP 54 case with PG gland
  • 1,8 kg
  • -10° bis +55° C
  • -20° bis +70° C
  • EN 12453 — safety of powered gates
  • EN 12978 — safety devices for powered gates