At power-on the new crushing point protector OSW-3 runs an initialisation test of all its optical characteristics. They are: rubber quality, gate width, amount of bending of the sensor as well as dirt on the optical parts of the unit. The result of the test is displayed via a blinking code of 1 to 16 pulses directly at the sensor unit. When the unit is working properly, a yellow LED is activated.
integrated diagnostics system with optical indicator
LED display of switching state
strengthened against wind pressure and bending
highly protected against EMV
protected against reverse voltage and electrical shorts
regulated transmission power
compatible with all common controllers
Technical data:
1...12 m
10...15 VDC, reverse voltage protected
ca. 40 mA
infrared, 880 nm pulsed
yellow LED for crushing point diagnostics blinks from 1 to 16 pulses
yellow LED, 'on' when crushing point is activated
pulsing push pull scanning, maximum load 10 mA
low level 0-1 V, high level 3-5 V
typical 900 Hz (0.5 kHz - 2k Hz)
transmitter: PA6-type plastic, receiver: Lexan, IR transmissive
PUR outer for 3 x 0.14 mm², D=3.4 mm, free of halogen, to nick stringy, acid and oil resistant