The circuit board has a flexible mounting. First all three screws need to be loosened by one turn (maximum length of screws is three turns). After adjustment, screws can be tightened.
Additional information!
Cable entry is pre-punched and can be opened manually. The rubber sleeve or the fixed cable mount can be used (both are included).
The case can also, depending on the mounting mode, be adjusted with three screws.
Isolator RD-20 for the reflector
Mounting bracket HW-R20 for the reflector
Mounting bracket HW-PZ for the retro-reflective switch
reflector with protection fogging- isolation
Retro-reflective Light Gate with polarising filter
range 0.5m - 15m depending on reflectory type
low sensitivity to stray light
high safety class
optimised cable connection
joint room
polarising optics
test input pins
reverse voltage protection
realy output
optics adjustable
dirt alert
optical adjustment via LED
Technical data:
15...36 V DC, reverse voltage protection
<100 ms nach U on
max. 30 mA/24 V
rot, 680 nm pulsed and polarised
approximately 1.5°
relay, two-way switch
min. 1 mA / min. 5 V DC
max. 0.3 A / 100 V AC
max. 0.5 A / 48 V DC (ohmic load)
<10 ms after detecting interruption of light beam
100 ms after detecting the light beam, the relay switches to ON.
brightness switching relay is activated when light beam is detected
0,5.....12 m
dual LED (red/green)
light beam interrupted = red LED
light beam active, operating limit reached = red LED blinks 4Hz
light beam active, within operating distance = greed LED is ON
test input (with 0V at pin 1, the transmitter shuts down)