Printable Version
TLS 250
The versatile suitable TLS 250 series can be used where point- or surfaceregistration happens. TLS250 sensores register the defined area with infrared rays. The sensores are always adapted to the current light enviroment by the intelligent electronic. Due this, the TLS 250 works even absolutely reliable at sudden reflexions or shadows.
Areas of application:
- Entrance doors for pedestrians
- Entrance gates in the industry
- Entrance doors in the industry
- Slide doors
- Bus/train doors
Technical data:
TLS250-N: Light sensor Range up to 4m
TLS250-NP: Light sensor Range up to 4m
TLS250-G: Light sensor Range up to 6m
TLS250-W: Light sensor Range up to 4m/Ellipse
TLS250-WP: Light sensor Range up to 4m/Ellipse

| Operating voltage |
12 ... 40 V DC |
|
|
|
|
|
| Reverse polarity protection |
yes |
|
|
|
|
|
| Current demand |
40 mA, 36 V DC |
|
|
|
|
|
| Relays |
48 V AC/1 A, 30 V DC/1 A |
|
|
|
|
|
| Range |
TLS250-N |
0,6 - 4m |
Ray |
0,3 m / at 2m |
calibration interval |
10s |
|
TLS250-NP |
0,6 - 4m |
Ray |
0,3 m / at 2m |
adjustable calibration interval |
3 - 600s |
|
TLS250-G |
1,3 - 6m |
Ray |
0,3 m / at 2m |
calibration interval |
10s |
|
TLS250-W |
0,4 - 4m |
Ellipse |
0,8 x 0,15 / at 2m |
calibration interval |
10s |
|
TLS250-WP |
0,4 - 4m |
Ellipse |
0,8 x 0,15 / at 2m |
adjustable calibration interval |
3 - 600s |
| Safety category |
IP 65 |
|
|
|
|
|
| Temperature |
-20°C .... +60°C |
|
|
|
|
|